Nortec RH2+ Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Nortec RH2+. Nortec RH2+ User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 62
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
RH2+
Installation and
Operation Manual
Includes installation, operation
maintenance and troubleshooting
information for your RH2+ Electric
Steam humidifier
2568051-F| 28 OCT 2014
Important: Read and save these instructions. This guide to be left with equipment owner.
Vue de la page 0
1 2 3 4 5 6 ... 61 62

Résumé du contenu

Page 1 - Operation Manual

RH2+ Installation and Operation Manual Includes installation, operation maintenance and troubleshooting information for your RH2

Page 2 - CYLINDER #

7 | Installation Location Mount on a suitable wall or vertical surface. Do not sit the unit on the floor. Allow clearances required for plumbing and

Page 3 - Contents

Installation | 8 Mounting with Keyholes 1 The RH2 humidifier is wall mounted using a keyhole located on the back of the unit cabinetry. 2 Use #8 x

Page 4 - Introduction

9 | Installation Plumbing Figure 6: Water Supply and Drain Connection  Supply water should at 30 to 80 PSIG and be between 150

Page 5 - Receiving and Unpacking

Installation | 10 Steam Distributor  Steam generated by the RH2 Space is blown directly into the space by the integrated blower pack. The RH2 Duct

Page 6 - RH2 Models

11 | Installation Figure 7: RH2 Duct Nozzle Distributor Installation Figure 8: RH2 Duct RSD10 Distributor Installation

Page 7

Installation | 12 Steam Lines and Condensate Return Instructions The following instructions must be followed for installation of steam lines for the

Page 8 - Installation

13 | Installation Figure 10: Main Steam Line Requirements MAIN RULES FOR ATMOSPHERIC STEAM LINES  Steam lines must not have

Page 9 - Typical RH2 Installation

Installation | 14 Figure 11: Steam Distributor Above Humidifier (Hose) Figure 12: Steam Distributor Below Humidifie

Page 10 - Location

15 | Installation Figure 13: Steam Distributor Below Humidifier With Obstruction (Hose) Figure 14: Common Steam Lin

Page 11 - Mounting with Keyholes

Installation | 16 Electrical Figure 15: Primary Power Connection Caution: Wiring to be performed by a licensed Electrician.

Page 12 - Plumbing

Thank you for choosing Nortec. Proprietary Notice This document and the information disclosed herein are proprietary

Page 13 - Steam Distributor

17 | Installation External Controls Control Wiring Controls are available from Nortec as accessories. If controls were not ordered with humidifier,

Page 14 - 11

Installation | 18 Space Humidification Control Location These instructions apply to the RH2 Space and the RH2 Duct with Remote Blower Pack.

Page 15

19 | Installation On/Off Control Wiring Figure 18: On/Off Controls Figure 19: Digital On/Off Humidistat

Page 16 - 1 in. (2.5 cm) pipe

Installation | 20 Modulating Control Wiring Figure 20: Modulating Controls Figure 21: Modulating Control Wiring

Page 17

21 | Installation Fan Enable Wiring When distributing steam into a duct, there can be a call for humidity when there is no air flow. Either the RH2

Page 18 - 15

Installation | 22 Options and Accessories Remote Blower Pack A remote blower pack is available for the RH2 Duct for applications where steam for humi

Page 19 - Electrical

23 | Start Up Start Up 24 Installation Check 25 On/Off or Modulating Operation 26 Start Up Procedure 27 Nortec Digital Controls 27 Modula

Page 20 - External Controls

Start Up | 24 Installation Check Before turning on power to the RH2 inspect the installation to ensure that it was carried out correctly. Refer to R

Page 21 - Installation

25 | Start Up On/Off or Modulating Operation From the factory the RH2 is configured to operate as an On/Off humidifier. It will run when 24 VA

Page 22 - On/Off Control Wiring

Start Up | 26 Start Up Procedure 1 Examine the humidifier and installation for damage and/or improper installation. 2 Ensure the cylinder is prope

Page 23 - Modulating Control Wiring

Contents 1 Introduction 2 Receiving and Unpacking 3 RH2 Models 4 Options and Accessories 5 Installation 6 Typical RH2 Installat

Page 24 - RH2 Fan Control

27 | Start Up Nortec Digital Controls Nortec provides optional On/Off and Modulating digital controls. Figure 26 show the function and meaning of

Page 25 - Options and Accessories

Start Up | 28 RH2 Pre-Start Up Checklist Unit Serial #: _________________ No. of humidifiers: _______ Tag: _______________ Unit type: _______ ____

Page 26 - Start Up

29 | Start Up RH2 Start Up Checklist Unit Serial #: _________________ No. of humidifiers: _______ Tag: _______________ Unit type: _______ ________

Page 28 - 25

31 | Operation Operation 32 LED Status Lights 32 Selecting a Relative Humidity Setpoint 33 Humidifier Components 34 Description of Component

Page 29 - Start Up Procedure

Operation| 32 LED Status Lights The RH2 user interface includes 2 LED’s which provide information about the humidifier status. Figure 27: LED S

Page 30 - Nortec Digital Controls

33 | Operation Humidifier Components Figure 28: RH2 Humidifier Components Steam OutletCondensate ReturnFill CupDrain ValveDrain CanalFill Valve

Page 31 - RH2 Pre-Start Up Checklist

Operation| 34 Description of Components Table 5: Humidifier Components Component Function of Component Blowerpack Disperses steam generated by the hu

Page 32 - RH2 Start Up Checklist

35 | Operation Humidifier Schematic Figure 29: Humidifier Schematic

Page 33 - Start Up

Operation| 36 How the Humidifier Works The RH2 is an atmospheric steam generator that uses heat generated by electrical current flowing between subme

Page 34 - Operation

1 | Introduction Introduction CAUTION: Servicing  Disconnect main power before any servicing.  The plumbing and electrical compartments con

Page 35 - LED Status Lights

37 | Operation Steam Line The steam line between the cylinder steam outlet and the distributor serves two purposes: it is used as a conduit to transf

Page 36 - Humidifier Components

Operation| 38 Humidifier Configuration The RH2 is factory configured to operate under most conditions without the need for any changes to its configu

Page 37 - Description of Components

39 | Operation On/Off or Modulating Control (J10) The RH2 output can be controlled by either an On/Off or a modulating humidistat. To set the RH2 to

Page 38 - Humidifier Schematic

Operation| 40 Maintenance and Servicing 41 Required Maintenance 41 Cylinder Spent Fault 41 Replacement Cylinder 42 Removing the Cy

Page 39 - How the Humidifier Works

41 | Maintenance and Servicing Required Maintenance The RH2 humidifier has been designed to require very little maintenance. Regular maintenance con

Page 40 - Condensate Return

Maintenance and Servicing | 42 Removing the Cylinder 1 Drain the existing cylinder by switching the On/Off/Drain switch to the Drain position. Let

Page 41 - Humidifier Configuration

43 | Maintenance and Servicing Drain Valve Cleaning Always clean the drain valve before installing a new cylinder. Scale from the spent cylinder may

Page 42 - Modulation Offset (J13)

Maintenance and Servicing | 44 Figure 36: Drain Valve Actuator Assembly Installing the New Cylinder 1 Insert cylinder into drain valve. Tilt cylin

Page 43 - Maintenance and Servicing

45 | Maintenance and Servicing Extended Shutdown Should it be required to disconnect power to the humidifier for a period of extended shut-down, alwa

Page 44 - Required Maintenance

Maintenance and Servicing | 46 RH2 Maintenance Checklist Model #: _________________ Serial #: _________________ Tag: ________ Cylinder #: CHE

Page 45 - Figure 34: Cylinder Removal

Introduction | 2 Receiving and Unpacking 1 Check packing slip to ensure ALL material has been delivered. 2 All material shortages are to be rep

Page 46 - Drain Valve Cleaning

47 | Troubleshooting Troubleshooting 48 Organization of Troubleshooting Chapter 48 Troubleshooting Requirements 49 General Troubleshooting

Page 47 - Installing the New Cylinder

Troubleshooting| 48 Organization of Troubleshooting Chapter The troubleshooting chapter is broken down into 2 sections. General Troubleshooting

Page 48 - Extended Shutdown

49 | Troubleshooting General Troubleshooting The following section provides general guidelines for troubleshooting the RH2 humidifier and auxiliary c

Page 49 - RH2 Maintenance Checklist

Troubleshooting| 50 Steam Distributors Symptom Cause Corrective Action(s) Distributor spitting out water 1 Distributor not level 1 Use support at

Page 50 - Troubleshooting

51 | Troubleshooting RH2 Faults The self-diagnostic system built into the RH2 is continually monitoring the operation of the humidifier. When an abn

Page 51 - Troubleshooting Requirements

Troubleshooting| 52 Table 8: Troubleshooting RH2 Faults (Continued) Yellow LED System Detected Cause Corrective Action(s) 2 flashes No Current Fil

Page 52 - General Troubleshooting

53 | Troubleshooting RH2 Wiring Diagram

Page 53 - Digital Humidistat

Spare Parts| 54 Exploded View and Spare Parts List RH2+ Spare Parts The Nortec residential humidifier model should be confirmed. The following s

Page 54 - RH2 Faults

55 | Spare Parts RH2+ Spare Parts The following spares parts are for RH2+ models only: tNortec Part No. Description 2560953 RH2+ Duct, 10lbs/hr, 1

Page 55

Spare Parts| 56 RH2+ Spare Parts The following spares parts are for RH2 models only: tNortec Part No. Description 2560953 RH2+ Duct, 10lbs/hr, 120/2

Page 56 - RH2 Wiring Diagram

3 | Introduction RH2 Models The RH2 is the most advanced residential steam humidifier available and provides steady and reliable humidification for a

Page 58

Warranty | 58 Warranty Nortec Humidity Inc. and/or Nortec Humidity Ltd. (hereinafter collectively referred to as THE COMPANY), warrant for a perio

Page 59

U.S.A. 1860 Renaissance Blvd Sturtevant, WI 53177 826 Proctor Avenue Ogdensburg, NY 13669 CANADA 2740 Fenton Road Ottawa, Ontario K1T 3T7 TEL: 1

Page 60 - 57

Introduction | 4 Options and Accessories Nortec provides a complete line of options and accessories for every humidification application. The follow

Page 61 - Warranty

5 | Installation Installation 6 Typical RH2 Installation 7 Location 8 Mounting with Keyholes 9 Plumbing 10 Steam Distributor 12 Stea

Page 62

Installation | 6 Typical RH2 Installation Figure 3: Typical Humidifier Installation 2

Commentaires sur ces manuels

Pas de commentaire